科学研究
学术论文
当前位置: 首页>>科学研究>>学术论文>>正文

    王子涵等Stable isotope labelling-flow injection analysis-mass spectrometry for rapid and high throughput quantitative analysis of 5-hydroxymethylfurfural in drinks

    2021-08-31 陈迪  点击:[]

    Stable isotope labelling-flow injection analysis-mass spectrometry for rapid and high throughput quantitative analysis of 5-hydroxymethylfurfural in drinks

    【作者】Zi-Han Wang, Jing-Xian Zhang, Ming Gao, Wei-Qi Cui, Lu Xu, Xiao-Lin Zhu, Jin-Jin Li, Zhi-E Huang, Dilshad Hussain, Jing-Yu Zhang, Di Chen*, XiaXu*

    【期刊名】Food Control

    【影响因子】2021: 5.548

    【作者单位】School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, PR China

    【年,卷():页码】2021, 130, 108386.-

    【关键词】Stable isotope labelling, Flow injection analysis, 5-ydroxymethylfurfural, Drinks, 3-Nitrophenylhydrazine

    【摘要】In this work, we reported a stable isotope labelling-flow injection analysis-mass spectrometry (SIL-FIA-MS) method for high throughput analysis of 5-hydroxymethylfurfural (HMF) content in drinks. 3-Nitrophenylhydrazine (3-NPH) and 13C6-3-Nitrophenylhydrazine hydrochloride (13C6-3-NPH) were used as pared labelling reagents to selectively label HMF. With a simple centrifugal operation, a certain volume of sample was directly mixed with 3-NPH solution. After adding a small amount of 13C6-3-NPH labelled HMF as internal standard, the sample can be directly transferred for the subsequent MS analysis owing to the contamination-free feature of excess 3-NPH. By using a multi-well thermostatic oscillator to carry out bath derivatization, the average time cost for each sample pretreatment was less than 1 min. Coupled with a triple-quadrupole mass spectrometer, FIA-MS with multiple reaction monitoring (MRM) was used for the rapid and high throughput detection of the labelled HMF in negative ion mode. The time cost for MS detection including injection process for each sample was about 1.5 min. Namely, the whole procedure including sample pretreatment and MS detection can be completed within 3 min per sample, which was very suitable for routine analysis for its high throughput and simplification. By labelling HMF with 3-NPH, the characteristic fragment ion after labelling and detection in interference-lesser negative ion mode enabled high detection specificity even without chromatographic separation. By using 13C6-3-NPH labelled HMF as internal standard to counteract the matrix effect during MS analysis, the detection accuracy and precision were guaranteed. In order to achieve the best conditions for the derivatization of HMF, several derivatization conditions including the acid concentration, the proportion of acetonitrile (ACN), the derivatization reagent concentration, reaction temperature and reaction time were investigated in detail. Under the optimized derivatization, quantitative analysis method was validated in ranges of 0.050–5.0 μg/mL. The relative standard deviations (RSDs) of inter-day and intra-day precision were less than 5.42% and 4.89%, respectively, showing satisfied reproducibility. The proposed method has been successfully applied to the analysis of HMF in sugar-sweetened drinks for feasibility verification in real samples.

    【全文链接】https://www.sciencedirect.com/science/article/abs/pii/S0956713521005247


    上一条:陈迪等A simultaneous extraction/derivatization strategy coupled with liquid chromatography–tandem mass spectrometry for the determination of free catecholamines in biological fluids
    下一条:韩文超等Application of natural cotton fibers as an extraction sorbent for the detection of trans-resveratrol in adulterated peanut oils

    关闭

版权所有:河南省靶向诊疗纳米药物重点实验室

地址:郑州市科学大道100号    邮编:450001