科学研究
学术论文
当前位置: 首页>>科学研究>>学术论文>>正文

    卜鑫淼等Matrix-assisted laser desorption/ionization high-resolution mass spectrometry for high-throughput analysis of androgenic steroid adulteration in traditional Chinese medicine based on d0/d5-Girard's reagent P labeling

    2022-12-13   点击:[]

    Matrix-assisted laser desorption/ionization high-resolution mass spectrometry for high-throughput analysis of androgenic steroid adulteration in traditional Chinese medicine based on d0/d5-Girard's reagent P labeling

    【作者】 Bu, Xin-Miao; Zhao, Wu-Duo; Zhang, Man-Yu; Wu, De-Qiao; Wu, Jian-Yuan; Xu, Xia*;Chen, Di*

    【期刊名】 Talanta

    【影响因子】 2021: 6.556

    【作者单位】 Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, PR China

    【年,卷():页码】2023, 253:124006.

    【关键词】Androgenic steroid; Stable isotope labeling; Matrix-assisted laser desorption/ionization; High-resolution mass spectrometry; Traditional Chinese medicine; Girard's reagent P (Carbazoylmethylpyridinium chloride)

    【摘要】The illegally adulteration of traditional Chinese medicine with androgenic steroids exposes consumers to multiple health risks. Therefore, it is very important to establish an accurate detection method. The current study presents a stable isotope labeling matrix-assisted laser desorption/ionization high-resolution mass spectrometry (SIL-MALDI-HRMS) method for high-throughput quantitative analysis of androgenic steroid adulteration. A pair of isotope labeling reagents (d0/d5-Girard's reagent P, d0/d5-GP) were employed to label steroids prior to MALDI-HRMS detection. The signal intensity was significantly improved, and the signal fluctuations were compensated by employing d5-GP labeled analytes as the internal standards. The limits of quantification (LOQs) of four steroids (nandrolone, testosterone, methyltestosterone, and testosterone propionate) were in the ranges of 0.180.48 µg/g. The calibration curves were obtained with acceptable linearities (R2 > 0.99). The relative recoveries ranged from 87.9% to 118.1%, and the intra-day and inter-day relative standard deviations (RSDs) were all less than 13.4%, which were satisfactory for quantitative analysis. The potential of the GP labeling strategy to improve the MALDI detection sensitivity was further demonstrated by the successful detection of cinnamaldehyde and 2’-methoxycinnamaldehyde in cinnamon-containing samples. Compared with the reported methods, the developed method proved to be high-throughput, highly selective, and accurate for androgenic steroids analysis in complex samples with good sensitivity.

    【全文链接】

    https://doi.org/10.1016/j.talanta.2022.124006


    上一条:于文艳等Carrier-free programmed spherical nucleic acid for effective ischemic stroke therapy via self-delivery antisense oligonucleotide
    下一条:张曼玉等Miniaturized kapok fiber-supported liquid extraction for convenient extraction of pesticide residues in vegetable oils: Determination of organochlorine pesticides as a proof-of-concept study

    关闭

版权所有:河南省肿瘤重大疾病靶向治疗与诊断重点实验室

地址:郑州市科学大道100号    邮编:450001