科学研究
学术论文
当前位置: 首页>>科学研究>>学术论文>>正文

    王蕾等A novel restricted access material combined to molecularly imprinted polymers for selective solid-phase extraction and high performance liquid chromatography determination of 2-methoxyestradiol in plasma samples.

    2017-10-19   点击:[]

    A novel restricted access material combined to molecularly imprinted polymers for selective solid-phase extraction and high performance liquid chromatography determination of 2-methoxyestradiol in plasma samples.

    【作者】Du, Bin; Qu, Tiantian; Chen, Zheng; Cao, Xiaohui; Han, Shuping; Shen, Guopeng; Wang, Lei

    【期刊名】Talanta

    【影响因子】 2014: 3.545

    【作者单位】 School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, PR China

    【年,卷():页码】2014, 129, 465-472

    【关键词】 Restricted access matrix; Solid phase extraction; Molecular imprinted polymers; 2-Methoxyestradiol; High performance liquid chromatography

    【摘要】A feasibility study was performed in order to ensure the possibilities in using a restricted access material combined to molecularly imprinted polymers (RAM-MIP) as sorbent material in solid phase extraction (SPE) for clean-up of 2-methoxyestradiol (2-ME) from plasma samples. The MIP with hydrophilic external layer was designed by precipitation polymerization. The polymer was characterized by thermogravimetric analysis (TGA) and scanning electron microscope (SEM). The use of analogs of 2-ME as templates, in combination with a chromatographic separation of the analytes in the sample, overcame the problem of the template bleeding. To demonstrate the property of the RAM-MIP obtained, a comparison of commercially available C18 SPE was performed. The results showed that the RAM-MISPE recoveries were significantly higher than that of C18 SPE for 2-ME in trace concentration. During the extraction process, 2-ME was sufficiently cleaned for further chromatographic analysis with no interferences from template leakage and matrix. Good linearity was obtained from 0.06 to 20 μg mL−1 with the correlation coefficient r>0.9991. The coefficient of variation of the inter-assay precision was less than 11.9%. The recoveries of 2-ME in rat plasma at three spiked levels were in the range of 99.10–101.00%. Based on the analytical validation results, the proposed method (RAM-MIP off-line SPE/HPLC) can be a useful tool to determine 2-ME in rat plasma samples.

    【全文链接】

    http://www.sciencedirect.com/science/article/pii/S0039914014003713


    上一条:杜斌等Multi-functional liposomes having radiofrequency-triggered release and magnetic resonance imaging for tumor multi-mechanism therapy
    下一条:侯琳等Transferrin-mediated fullerenes nanoparticles as Fe2+-dependent drug vehicles for synergistic anti-tumor efficacy

    关闭

版权所有:河南省靶向诊疗纳米药物重点实验室

地址:郑州市科学大道100号    邮编:450001